Any idea of the problem?? I have a t-15 cell. Could this be an issue with my pump? The filter timer will not turn on at all, even when trying manually but the cleaner does. Are you using enough DE powder? The volute screws (around the impeller housing) do not need to be removed. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. My Hayward pump is only about 3 yrs old. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. Step 2: Did you properly install your switch? That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. Capacitors are cheap to replace, or you can test the capacitor I have it set on a timer and when the pump comes on the flow rate is good but as the day goes on it becomes less and less. No lubricant is needed for spider gaskets. If valve is open when it should be closed the heater will shut down and go into lockout. Round about 1990 the original AG pump and filter were replaced with used Hayward IG equipment. Backwashing or cleaning the pump basket is the usual fix. Yes, kind of does defeat the purpose, but you may not need to heat the pool all the time, so can still run on low-speed for many hours per day. Check that hoses are clamped tight to fitting. Hi Sal, for the pump lid, it may help to close the incoming and outgoing valves, and open the filter air bleeder, to release the suction. Remove the cover plate, and use an insulated screwdriver to discharge the capacitor. Went to start the pump to prep the pool for the kids and sill attempt to turn on but then stops. search, pool & drain cover safety In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. The regular tristar is only $100 cheaper now, so Id go for the Tristar VS. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. The heat sink is a ridged metal plate beneath the drive, that relies on air flow to help remove heat from the motor. Could be insects or the copper arms are bent, or something caught up in the works, This is usually directly in the center of the motor a centrifugal switch, steel with side springs, and a triangular shaped switch attached at 6 oclock, but contacting the cent. Did you figure this out. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? How To Recalibrate The Average Salt Level. I have been getting GFI breaker trips intermittently. Just put he new motor on and its still not working, sounds like power is being sent to the motor, but nothing. Any ideas how to address this? The impeller does not need to be spun on too tight, the spin direction of the shaft will keep it snug, so just hand tight. When they fail, they often crack, bulge, leak or smell bad, but not always. Got pump from a friend and he had no problems. You can get locally at an electric motor repair shop. Hi, if the spark/flame was where the plug meets the cord, it could be a plug problem or an outlet problem. I put the pump back together and it still leaks. when i reassemble after cleaning, pump works great for about 5 mins even at 30 psi. The motor had stopped when I checked in morning. Hi when you say it shuts down, I assume you mean that the water stops flowing? News Reporter Reveals On Live TV That Shes Been Secretly Recording . Move switch to center position and adjust dial to a percentage that you think it needs. Not sure if I need to purchase a new pump. RPS. Power on LED is intermittently on or off. At first, the pump would only hum and not work. Or using a Clarifier after vacuuming can also be a solution. Check it out, it could start a fire! More commonly, you may experience sparks, or a small popping sound as you drain the capacitor, if there is a lot of power stored. Replace the seal in the same orientation as you removed it, and reassemble. When the pool guy switched it, it worked very well for about a month with no issues at all. Getting ready to start up my pool , flipped the breaker and nothing. Run motor with impeller alone for brief second, sounds perfectly quite and normal.
) and you should be able to feel debris lodged in the impeller with your fingertips. No noise, nothing. It likely also got hot and the threads shrunk, now drawing in too much air for the pump to catch prime. Per your article, it sounds like I need a new capacitor. I just went out there to crank them up, after 10 minutes they shut off. We just opened our pool up cleaned everything out put new D.E. I keep reading that it could be a seal. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. could be cord problem, too. I connected the pump to a nearby receptacle with a heavy duty drop cord and it works fine. Also check other wires in the back of the motor. Well, you first need to inspect it, and if the parts are broken, replace them. Unlike the error codes that show up on the digital screen, these problems dont show up as an error notification. I even tried running the new line downhill and then back up some to hold water in the piping. They dont typically make noise for long either, because at 3400 RPM, if the impeller is hitting something, it will quickly wear it down. Could the water have damaged the motor ? Mine hums and then trips the breaker. Filter. Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? The fuse is meant to protect the heater from 115V, as the voltage past the fuse should be like 28V, stepped down after the transformer. Reassemble pump in reverse order from above. Could need cleaning. "url": "https://intheswim.com/",
Tried to backwash. If the gears are moving, then power should be coming out of the timeclock to the motor. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. "caption": "In The Swim Blog"
Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. You will get much more visibility by. On Jandy valves, the spurt may be from the lid, or from the center of the lid around the stem, from a broken or missing grease cap (grey valves), or from a crack/damage. I turn it off at the breaker & then turn it back on again, it displays rESET. If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. Look closely for any visible damage in the rear of the motor, anything loose, disconnected, chewed, melted, broken, burnt or cracked. The waste tube on my filter is filler while my pump is running. Please help. As I started to prep for this season, I did notice that the positive and negative electrical terminals on the 3 prong cord were corroded and loose. One thing you can attempt is a superglue repair, which I have done successfully on many multiport valves, but not on a pump body. Flipped the breakers back on this morning after problem fixed. When corrected, control will run blower for 5 s then automatically restart after 2 minutes. Shaft seal went out twice and I have a groove in the motor shaft now. When I tighten the impeller onto to the motor how tight should it be? I presume Ill be looking at buying a new pump next year. Hello, I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. Replace with identical MFD number, printed on capacitor. Automatic reset is 60 minutes. 3. One washer on each side of the spring, you are correct. I removed the back of the pump and the yellow wire has a small black burn hole in it. Sometimes its the filter that is drawing in air, thru the air bleeder or clamp band or bulkhead, which causes the filter to drain out through the pump, and back to the pool. If so, you need stronger hose (or pipe), or add another suction pipe (and wall fitting). I believe I checked everything and hoping its just the electric cord and the fact that it is corroded and loose and likely loosing electric current after it gets heated up a bit. I bought same pump and electrician put on old twist lock cord from previous pump. Went out today to find the lower plastic shroud melting again? If there isnt any apparent damage, keep reading. Inspect for any damage to wires or wire casing. Turned on the motor and smoke and a oil type substance came out of the capacitor. When, Swimming pool pumps that are noisy can keep you from enjoying peaceful naps by the pool, or can keep your neighbors up, In-Floor pool cleaners have been around since the 70's when they became the answer to the complaints about traditional pool cleaners. 2. I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Quite a criticism for something costing 33bn-plus. Even the power light is not on. If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. Missing standpipe o-ring In the last couple weeks it started getting louder at various times throughout the day. Is it time for a replacement pump? Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Either way, when a DE filter clogs up quickly, it is either not enough DE powder being used, or the grids (flex tubes for Perflex) are clogged with mineral scale or oily deposits. I They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. I have my pump to run each evening from 10:30pm to 9:30am. Articles and resources for swimming pool owners and DIYers. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. I hope to hear back from you I have a Hayward Super II pump that has had a small leak between the pump housing and seal plate.